Optical ConfigurationClear Aperture 30 mmApplicable Wavelength 1070~1080 nmMax. Laser Power 8000 WFiber Connector QBHCollimating Focal Length &nbs
Optical Configuration
Clear Aperture 30 mm
Applicable Wavelength 1070~1080 nm
Max. Laser Power 8000 W
Fiber Connector QBH
Collimating Focal Length F125, F150
Field Lens Focal Length F420 (F254, F330)
Field Lens Working Distance 531 mm
Scanning Range 207 x 207 mm
Null Position Error < 5 mrad
Gain Error < 5 mrad
Dynamic Parameters
Following Error 0.65 ms
1% Full Scale Step Response 1.5 ms
10% Full Scale Step Response 3.0 ms
Typical Marking Speed 2.5 m/s
Typical Positioning Speed 13.5 m/s
Accuracy Parameters
Repeatability <2 μrad
Null Drift < 15 μrad/K
Gain Drift < 25 ppm/K
Cooling Method Water cooling & Air cooling
Power Supply 24V DC, max. 5A
Galvanometer Control Protocol XY2-100_FB
Weight Approx. 11.5 kg
Typical Applications Thick plate welding, high-strength material welding
暂无文档资源
暂无软件资源